FOB Price
Get Latest Price|
1 Minimum Order
Country:
China
Model No:
AS1
FOB Price:
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
1
Packaging Detail:
TBA
Delivery Time:
TBA
Supplying Ability:
-
Payment Type:
L/C, T/T
Product Group :
Contact Person Mr. Nuo
Huanghe Road, Kaifeng, Henan
Air which was sucked in from air intake tower enters the suction
air filter and after being removed of dust and other mechanical
contaminants in it, it is compressed to the pressure of 0.*5MPa by
centrifugal air compressor. Air from the air compressor is cooled
to *0℃ in the direct contact after cooler and refrigeration unit
after the water being separated its condensed water, taken into the
molecular sieve adsorber for removing H2O, C2H2 and CO2. There are
two molecular sieve adsorbers which operate on a staggered cycle,
i.e. one vessel is adsorbing the contained impurities while the
other is being reactivated by waste nitrogen from the rectifying
column.
Then the cleaned air is divided into two streams, one of them is
taken into the rectifying column and cooled by the returned waste
nitrogen, oxygen and nitrogen through the main heat exchanger. The
steam-liquid air mixture is taken into the lower column for
rectifying, and herein the pure nitrogen of *9.*9% from the top of
the column enters into the evaporator-condenser and condensed by
liquid oxygen from the upper column. A part of the liquid nitrogen
is fed to the lower column as reflux. The other part is divided
into two streams, one of them after subcooling enters into the top
of the upper column after throttled, the other enters crude argon
condenser of crude argon column, after vaporized, it enters in
upper column.
Another cleaned stream is compressed in booster end of the booster
expansion turbine, and then enters the main heat exchanger. Two
streams of air from the middle and cold end of the main heat
exchanger joint together and enter into the turbine expansion to
generate most refrigeration for need of the plant's operation.
After the expanded air is removed of overheat through the
thermosyphon heat exchanger, it enters to the middle of the upper
column for rectifying.
A stream of 8% Ar is drawn from middle-lower section of upper
column and enters Crude Argon Column I to be rectified. Gas is
drawn from top of Crude Argon Column I and enters Crude Argon
Column II, then enters condenser as its reflux. The liquid at the
bottom of Crude Argon Column II is pumped into top of the Crude
Argon Column I as reflux, the crude argon is drawn from Crude Argon
Column I and enters heat exchanger then enters pure argon column,
pure liquid argon of *9.*9% Ar is drawn from bottom of pure argon
column and enters Lar storage & gasification
system.
The product oxygen with the purity of *9.8% O2 gained at the bottom
of the upper column is warmed up through the heat exchanger and
then delivered to the compressed oxygen system.
The LOX of *9.8% O2 is drawn from oxygen side of the
evaporator-condenser, some of them enters storage tank as product.
The product nitrogen of *9.*9%N2 from recycle N2 compression system
is supplied to the user for use.
The waste nitrogen from the top of the upper column is warmed up,
one part goes to the regeneration molecular sieve adsorber, another
goes to waste nitrogen tower to cool the water.