System function
Throughput: up to **0 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted
at any time. Test sequence can be sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes,
maintenance free
Cuvette washing: auto wash the cuvettes through 6 segments
washing pipe and continuous use them, and each cuvette
wash *2 times before use it again
Reaction detect: monitor *1 cuvettes’s reaction at the same
time
Photometric process: the interval time between two
consecutive photometric points are exactly thesame
Pipeline system: pressure auto released pumps and double
filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of
positioning of moving parts
Environmental resistance: resistant form dust and water
vapor
Sample/Reagent/Stirrer system
Sample volume:2μLï½�*0μL, step by 0.1μL
Sample disc: *0 positions for primary tubes and secondary
cups
Sample probe: inner and outer walls are highly polished
leads carry-over<0.1%, level
detectionand vertical and horizontal collision
protection
Sample tube: bothprimary tubes and secondary
cups are suitable
Reagent volume:*0μLï½�**0μL, step by 1μL
Reagent disc: provide *0 reagent bottle
positions
Reagent probe: inner and outer walls are highly
polished leads carry-over<0.1%,
level detectionand vertical and horizontal
collision protection
Reagent bottle: particular reagent bottle
without dead volume
Reagent Cooling: continuous cooling system according to
the principle of peltier
Stirrer: paddle stirrer coated with Teflon, stir
immediately after the sample was added in
Water
consume:<6L/hour
Carry over: Optimized item test sequence and reinforced
washing process, lower the carry overand avoid
probe being clotted
Reaction system
Cuvette: permanent UV free glass cuvette
Reaction disc: Discal reaction disc with
*1 disposable cuvettes
Reaction volume:**0μLï½�**0μL
Heater: solid and sealed heater leads temperature raise
rapidly and steady and maintenance free
Temperature: *7℃±0.1℃
Optical system
Light source: *2V *0W, halogen lamp with lifetime more than
***0 hours
Spectrometer: post spectrometer with arrayed and sealed
filters, maintenance free
Wavelength: **0nm, **5nm, **0nm, **0nm, **6nm, **8nm, **0nm,
**0nm
Absorbance range: 0�6
Calibration/QC
Calibration type: single point linear, two points linear,
multi-points linear, Logit*4P, Logit*5P, Spline, Exponential
5P, Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC, daily QC, day to day QC
QC chart: L-J,Cumulative sum check, Twin Plot
QC rule: Customized QC rule in order to adapt
different item’s requirements
Operational system
Operational system: VISTA, Windows XP, Windows***0
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the
analyzer
Power/ Dimension
Voltage: AC *5Vï½�**4V, *5Hz±8Hz, Auto adapt
according to the voltage
Power Consume: ≤**0VA
Dimension: 9*0mm×**2mm×***0mm
(L×W×H)
Net weight: **0Kg