FOB Price
Get Latest Price( Negotiable )
|1 Unit Minimum Order
Country:
China
Model No:
C30
FOB Price:
( Negotiable )Get Latest Price
Place of Origin:
guangdong
Price for Minimum Order:
-
Minimum Order Quantity:
1 Unit
Packaging Detail:
export carton
Delivery Time:
3-5 days
Supplying Ability:
1000 Unit per Month
Payment Type:
T/T, Western Union, Money Gram
Product Group :
-
Contact Person Mike
Shenzhen, Guangdong
Working principle
*0K Strong sound waves explosion head effectively promote the
organization fat metabolism, repel orange peel fat, firming
skin,enhancing skin elasticity, etc. And the effect is long
lasting. The *0 K sound waves can make a implosion of liquid as
the expansion and compression of the wave make the inside of
the liquid formed in many small space and what inside this kind
of space are gas and steam. During the compression cycle, the
*0K sound waves have positive pressure effect on the liquid
molecules, while during the expansion cycle the *0K sound waves
have positive pressure effect on the liquid molecules. There
are cohesion inside of liquid or and biological organization.
Inside of the low density fat cells, the cohesiveness of the
molecular is weaker.The low negative pressure which is produce
by *0 K sound waves will produce organization gap which is
called"cavitation phenomenon"inphysics. The implosion of inside
and outside of the cells will enhanced the molecular motion and
achieve a high energy level, and eventually led to the bursting
of the fat cells.
*0K cavitation operation procedure
Click "STRONG SOUND WAVE SYSTEM" enter the operation
interface.
1. System default working time is *0 minutes, time range is
0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked
time is used to record the total time of the instrument worked.
Before working, it will be 0 minute.
3. The system default Intensity is 0.The intensity range is
0~5(standard parameters), press one time to change one unit of
standard parameters.
4. The system default output of band is the third one
(Continuous band), you can choose the band by click the band
mode.
5. Click"START", it starts working and"STOP"for stop working
Press"BACK", you can get back to the operation interface.
6. Beautician hold the cavitation explode work head to move
slowly on skin, in circle or beeline repeatedly
7. Do not use on back, avoid using on bones.
8. Do not use on uterus part when women do abdomen care.
Abdomen treatment during menstruate should be avoided.
9. The machine will pause automatically if the setting time is
over. Please click any place of the screen According to the
hint.
*0. Clean the leftovers with hot towel, use warm towel to clean
the cavitation explode work head.
Caution for using *0K
1.Applied enough gel on skin need treated.
2.Do not stay unmoved on any part of your body ,do not stay on
bones.
3.The total treatment time for daily should be within *0
minutes.
4.There will be ultrasonic only when you step on the service
brake while using *0K cavitation explode work head.
5.Do not allowed to be placed under the state of no-load to
avoid the damage caused by high heat.
6.*0K work head can be used on fresh part of the body, Do not
use for facial. If the skin is sensitive or becomes unhealthy,
the strength of the power should be adjusted down.
Skin rejuvenation principle
The circulation medical radio frequency system in 1 seconds
will change the electric polarity in electric field millions
times of the biological tissue of the therapeutic part ,
particles of the organization will do Brownian motion(molecular
no rules movement) as the same frequency which will make the
organization produce columnar distribution of heat, damage
collagen hydrogen bonding structure and change the collagen
molecules of the three spiral structure, and lead to the
immediate collagen sex contraction and as a result of the
treatment effect of firming skin;
According to ajusting the energy output, the circulation system
makes skin tissues have mild, moderate and severe heat
aggression three stages which is similar as the three stages in
wound healing (inflammation stage, growth stage, remodeling
stage), improve leather remodeling shape, so as to reconstruct
the skin and dispel light, medium, heavy wrinkles uteruses
Calvin lines and the skin flabby after losingweight. The effect
is long lasting.
De-fatting body slimming principle
The medical circulation RF
system will produce columnar distributed hea in the
subcutaneous tissue and fully make triglycerides release from
the fat cells. Under the action of lipase the triglyceride will
cracking into fatty acids and glycerin,then eliminated from the
body along with the metabolism. Because of the intelligent
system, the medical circulation rf instrument can orientate the
fat cells, and release triglycerides quantificationally, thus
achieved the localization, the effect of reducing weight
rationally and quantificationally.
Multipolar RF system operation
1. System default working time is *0 minutes, time range is
0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked
time is used to record the total time of the instrument worked.
Before working, it will be 0 minute.
3. The system default Intensity is 0. The intensity range is
0~*0w /cm2,press one time to change one w/cm2.
4. The system default output of band is the third one
(Continuous band),you can choose the band by click the band
mode.
5. Click"START", it starts working and"STOP"for stop working
Press"BACK", you can get back to the operation interface.
Multipolar RF system-face
Click the third module'MULTIPOLAR RF SYSTEM-FACE"
1. System default working time is *0 minutes, time range is
0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked
time is used to record the total time of the instrument worked.
Before working, it will be 0 minute.
3. The system default Intensity is 0. The intensity range is
0~*0w /cm2,press one time to change one w/cm2.
4. The system default output of band is the third one
(Continuous band),you can choose the band by click the band
mode.
5. Click"START", it starts working and"STOP"for stop working
Press"BACK", you can get back to the operation interface.
Caution for using RF
1.Beautician should wear insulated gloves during operation.
2.Do not wear any aglet, both for the beautician and the
users.
3.The electrode probe must be fully in contact with skin.
4.Do not make the RF electrode stay on any part without moving.
Keep it moving on skin slowly.
5.Skin around eyes and forehead is very thin, the RF output
intensity should be relatively weakened.
6.Do not contact skin with unipolar when using of bipolar,
tripolar,hexpolar RF work head otherwise it will produce pulse
discharge, gel paste etc. Products like gel maybe evaporated
into a mist.
Voltage: **0V/**0V***0V/**0V
Frequency: *0 Hz - *0Hz
Power: =*5W
Output RF: 5MHz
Output supersound: *0KHz
Body materials: PVC plastic
1. Mainframe 1
2. Power line 1
3. *0K cavitation explode work head 1
4. Hexpolar RF laser work head for body 1
5. Tripolar RF work head for face 1
6. Accessories bracket 1
Country: | China |
Model No: | C30 |
FOB Price: | ( Negotiable ) Get Latest Price |
Place of Origin: | guangdong |
Price for Minimum Order: | - |
Minimum Order Quantity: | 1 Unit |
Packaging Detail: | export carton |
Delivery Time: | 3-5 days |
Supplying Ability: | 1000 Unit per Month |
Payment Type: | T/T, Western Union, Money Gram |
Product Group : | - |