Product Description
HY***7系列温控器使用说明书。
1. Overview:Â
HY***7 series temperature
controller is used to control the terminal system of large and
small central air conditioning, mainly by adjusting the air
volume of the terminal fan coil unit, the switching state of the
water valve and the control of the air valve of the air duct
unit, so as to achieve the purpose of adjusting the indoor
temperature.Â
This series adopts mechanical
diaphragm control technology, through the principle of thermal
expansion and cold contraction of diaphragm, it has the
advantages of accurate control, economy and
practicality.Â
With cold and warm switching, room
temperature detection, automatic control of fan or air valve
function.Â
2. Model and function:Â
Type No. fan speed air valve switch
water valve switch stop fan.Â
HY***7 manual three-speed
automatic.Â
HY***7Y manual three-speed
automatic.Â
3. Main characteristics and
technical indicators:Â
Item gauge grid.Â
Control object AC fan, water valve,
air valve, etc.Â
Operating voltage AC**0V ±*5% *0max
*0HZ.Â
Rated current 3 (2) A.Â
Set temperature range from *0 ℃ to
*0 ℃ (continuously adjustable).Â
Working temperature range 0 ℃ ~ *0
℃.Â
Working humidity when ambient
temperature is *0 ℃, humidity ≤ *0%.Â
Control precision ±1
℃.Â
Wood quality milky white PC
plastic.Â
Shape and size
**8mmX*5mmX*8mm.Â
4. Wiring diagram:Â
5. Install the
instance.Â
(1) remove the shell.Â
6. Appearance size:Â
7. Points for
attention:Â
The wiring must be described in
strict accordance with the wiring diagram.Â
It must be installed in a
well-ventilated location with an elevation of 1.5 meters above
the ground.Â
Avoid installing the thermostat at
the air outlet, where there is sunlight or where there is a cold
/ heat source.Â
Please install this product
vertically. Please confirm the upper and lower position before
installation.Â
All wiring works should be
completed before electricity is turned on.Â
Please reconfirm that the wiring is
correct before the power is turned on after the completion of the
wiring.Â
The installation and wiring of the
surface shell should be undertaken by electrical
professionals.Â
The terminal can accept a wire up
to 1.5m thick.
Â
HY***7 series thermostat
instruction manual.Â
1. Overview:Â
HY***7 series temperature
controller is used to control the terminal system of large and
small central air conditioning, mainly by adjusting the air
volume of the terminal fan coil unit, the switching state of
the water valve and the control of the air valve of the air
duct unit, so as to achieve the purpose of adjusting the indoor
temperature.Â
This series adopts mechanical
diaphragm control technology, through the principle of thermal
expansion and cold contraction of diaphragm, it has the
advantages of accurate control, economy and
practicality.Â
With cold and warm switching,
room temperature detection, automatic control of fan or air
valve function.Â
2. Model and
function:Â
Type No. fan speed air valve
switch water valve switch stop fan.Â
HY***7 manual three-speed
automatic.Â
HY***7Y manual three-speed
automatic.Â
3. Main characteristics and
technical indicators:Â
Item gauge grid.Â
Control object AC fan, water
valve, air valve, etc.Â
Operating voltage AC**0V ±*5%
*0max *0HZ.Â
Rated current 3 (2)
A.Â
Set temperature range from *0 ℃
to *0 ℃ (continuously adjustable).Â
Working temperature range 0 ℃ ~
*0 ℃.Â
Working humidity when ambient
temperature is *0 ℃, humidity ≤ *0%.Â
Control precision ±1
℃.Â
Wood quality milky white PC
plastic.Â
Shape and size
**8mmX*5mmX*8mm.Â
4. Wiring diagram:Â
5. Install the
instance.Â
(1) remove the
shell.Â
6. Appearance size:Â
7. Points for
attention:Â
The wiring must be described in
strict accordance with the wiring diagram.Â
It must be installed in a
well-ventilated location with an elevation of 1.5 meters above
the ground.Â
Avoid installing the thermostat
at the air outlet, where there is sunlight or where there is a
cold / heat source.Â
Please install this product
vertically. Please confirm the upper and lower position before
installation.Â
All wiring works should be
completed before electricity is turned on.Â
Please reconfirm that the wiring
is correct before the power is turned on after the completion
of the wiring.Â
The installation and wiring of
the surface shell should be undertaken by electrical
professionals.Â
The terminal can accept a wire up
to 1.5m thick.
Country: |
China |
Model No: |
HY1007
|
FOB Price: |
( Negotiable ) (Negotiable)
Get Latest Price
|
Place of Origin: |
Beijing |
Price for Minimum Order: |
- |
Minimum Order Quantity: |
1 Piece |
Packaging Detail: |
- |
Delivery Time: |
- |
Supplying Ability: |
- |
Payment Type: |
Other |
Product Group : |
- |