FOB Price
Get Latest Price|
- Minimum Order
Country:
China
Model No:
-
FOB Price:
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
-
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
-
Payment Type:
-
Product Group :
-
Contact Person Summer
No.6,Xianggong Road, Hongwan Industrial Park, Xiangzhou, Zhuhai, Guangdong
1. Description
CKWB is a three-phase AC smart outdoor vacuum
breaker use vacuum interrupter for arc extinguishing and
SF6gas
for insulation. It can work in the range of rated voltage maximum
up to *4kV.
2. Working Condition
2.1 Ambient air temperature:
**5℃~**0℃,daily range of temperature: diurnal variation
*5℃
2.2 Relative humidity: daily average data ≤*5%,
monthly average data ≤*0%
2.3 Seismic capacity: ≤magnitude 8, horizontal
acceleration ≤ 0.4g, vertical acceleration ≤ 0.2g
2.4 Altitude: ≤***0m
2.5 Pollution
classification:IV.
2.6 Wind speed: ≤*5m/s
2.7 Applicable in the places without obviously
pollution, fire, explosion risk and violent
vibration.
(Exceeding above working condition is available
as customized product)
3.Technical Data
Description | Unit | Parameter |
Rated voltage | kV | *2 |
Rated frequency | Hz | *0 |
Rated current | A | **0 |
Rated short-time withstand current(4s) | kA | *0 |
Rated peak withstand current | kA | *0 |
Rated short-circuit making current(peak) | kA | *0 |
Rated short-circuit breaking current | kA | *0 |
Breaking times for rated short-circuit breaking current | times | *0 |
Rated current breaking time | times | ****0 |
Power frequency withstand voltage(1min) | kV | *2/*8 |
Lighting impulse withstand voltage | kV | *5/*5 |
Clearance between open contacts | mm | 9±1 0.5 |
Overtravel for contacts | mm | 3±0.5 1 |
Opening speed | m/s | 1.2±0.2 |
Closing speed | m/s | 0.6±0.2 |
Bounce time for contacts closing | ms | ≤2 |
Opening simultaneity for three-phase | ms | ≤2 |
Resistance for each phase conductive circuit | uΩ | ≤**0 |
Closing time | ms | *0~*0 |
Opening time | ms | *8~*0 |
Rated power for stored-energy electromotor | W | ≯*0 |
Rated voltage for stored-energy electromotor | V | AC**0 |
Rated operating voltage for closing/opening | V | AC**0 |
Max./ Min. operating voltage for closing | V | AC**4/**3 |
Max./ Min operating voltage for opening | V | AC**4/**3 |
Max./ Min. electromotor operating voltage | V | AC**2/**7 |
Mechanical life | times | ****0 |
SF6gas gauge pressure SF6 | Mpa | 0 |