Disposable Circular Stapler
The circular stapler is used in general surgery, thoracic surgery,
surgical treatment of obesity and in colo-rectal surgery, to
perform end-to-end, side-to-end, and side-to-side anastomoses.
The stapler utilizes titanium staples in circular staggered
assembly of two concentric rings inside the staples-containing
cartridge. The circular blade automatically cuts off any tissue
excess during staple release and creation of circular anastomosis.
The stapler can be easily operated by complete squeeze of the
trigger handle. Dimension of anastomosis is defined by the size of
the selected circular staples-containing cartridge.
Compact construction and modern design concordant with modern
standards ensure patients and users safety
1?Function and Application
Our Circular Stapler can easily and conveniently anastomose lumen
organs by firing into the tissues of alimentary canal two staggered
(interior and exterior) rings of titanium staples and cutting off
inside tissue with the circular blades simultaneously.
This circular stapler is suitably used for end-to-end and
end-to-side tissue anastomoses in alimentary canal organs such as
esophagus, stomach , entera etc., especially at the low recta and
high esophagus not suitable for hand work. It also can be used in
the circular cutting operation of hemorrhoids.
2?Configuration
Circular Stapler mainly consists of anvil closure assembly and
staples firing assembly. Turn the adjusting knob clockwise, bring
the anvil to move horizontally to the circular blade assembly by
lead screw, adjust the gap between them to a proper scale
(1.0mm~2.5mm, it can be seen from the firing indicator window),
then open the safety, squeeze the firing handle with a firm and
steady pressure to fire and anastomose.
In order to guarantee blood supply of the anastomosed tissue, the
Circular stapler can adjust the closure gap (ranging from 1.0mm to
2.5mm) according to the thickness of the tissue to be anastomosed.
In addition, in order to avoid firing beyond the range set
beforehand, circular stapler has a safety and the safety can be
opened only when the gap is between 1.0mm and 2.5mm.
For the sake of security, this instrument is designed to complete
stitching and cutting at the same time. The circular blades will
automatically cut off otiose tissue when the instrument is fired
and circular anastomosis will be formed.
3?Precautions
This Circular stapler is sterilized by γ-ray and is supplied for
clinical use in a sterilized packing.
(1) Be sure to check the packing of this product carefully before
use. Stop using it if the packing bursts.
(2)This Circular staplers is for One patient only, so it mustnt be
used again though sterilized.
(3) Make sure the Circular Stapler is within the period of validity
(three years after sterilized).It is strictly prohibited to use the
product beyond the expiration date.
(4) The sterilized products must be stored in a dry room with
excellent ventilation and without caustic gases.
Country: | China |
Model No: | RD |
FOB Price: | Get Latest Price |
Place of Origin: | China |
Price for Minimum Order: | - |
Minimum Order Quantity: | 1 Piece |
Packaging Detail: | - |
Delivery Time: | 3-6days |
Supplying Ability: | - |
Payment Type: | T/T |
Product Group : | - |