FOB Price
Get Latest Price8800 ~ 28800 USD / Set
|1 Set Minimum Order
Country:
China
Model No:
GC5890N
FOB Price:
8800 ~ 28800 USD / Set Get Latest Price
Place of Origin:
-
Price for Minimum Order:
8800 per Set
Minimum Order Quantity:
1 Set
Packaging Detail:
standard export package
Delivery Time:
7 days after received deposit
Supplying Ability:
500 Set per Month
Payment Type:
Western Union, D/P, D/A, L/C, T/T
Product Group :
Contact Person JESSIE
Changsha, Hunan
Product
Description
  The
GC***0NGas
Chromatograph is a new generation network-based gas
chromatograph which is built on international advanced technology
with instruments advantages, technological innovation and
comprehensive upgrade.
   Fully compatible
with the Agilent ***0N gas chromatograph, GC***0N can be directly
connected with Agilents hydrogen flame ionization detector, thermal
conductivity detector, electron capture detector, flame photometric
detector, nitrogen phosphorus detector (NPD) and detector control
panel. The instrument specifications, the performance and the
detector sensitivity of GC***0N can be comparable with the Agilent
***0 GC. GC***0N can also be connected to the Agilents
chromatography workstation and auto sampler.
Â
Application
area
GC***0N can be used in the
petrochemical industry, the food area, the pharmaceutical
industry, the environmental
protection department, the CDC field, the food safety supervision
department, the water company, the electric power company,
metallurgical industry, scientific research institution and quality
inspection department etc.
Â
Features
Proven high precision and
multifunction and connected with international advanced
technology
The temperature control accuracy
can be precisely to
0.*1℃ by the new integrated digital electronic
circuit with high control precision and reliable
performance.
GC***0N has self-diagnosis
function, stopwatch function, operating timer function, power
storage protection function, keyboard locking function, power
anti-interference function, network data communication and remote
control function.
Â
Got lower limit of
detection by unique injection system design
The unique inlet design can solve
sample discrimination;
Double column function can not only
settle program drifts problem causing by temperature rising,
but also can reduce the effect of background noise and it can also
get lower limit of detection;
It owns packed column and capillary
split/non-split injection system (which has membrane cleaning
function);
You can choose auto/ manual *-way
valve gas injection, headspace injection, thermal
desorption injection, cracking furnace injection, methane
conversion oven or autosampler.
Â
Controlled precisely of
heating procedure and furnace temperature making the program
steadiness, balance and speediness
After the temperature rising or
cooling, the program
shortens all detector systems stable equilibrium time by large
capacity column oven and intelligent backdoor system;
Heating furnace system:
environment temperature + 5℃~**0℃; heating rate 0.1~**0℃/min; furnace temperature can be recalibrated
by users, max temperature can be set within **0℃, temperature equilibrium time of heating
furnace can be decided by users;
Â
Satisfied different plans for high
sensitive and stable detectors
It can install FID, TCD, ECD, FPD,
NPD and PDHID;
All detectors can control
temperature individually;
Easily to clean and replace
the nozzle, FID can also be disassembled and installed
expediently;
TCD stable time:≤*0min
Â
Technical
index
Column
Oven
Â
Dimensions: | *8× *0× *8 cm |
Operating temperature range: | ambient temperature*5 ~ **0℃ |
Temperature setpoint: | 0.1℃; programmed heating rate 0.1℃ |
Maximum heating speed: | **0℃/min |
Temperature stability: | It will be 0.*1℃, when the environment temperature changes a centigrade |
Programmed temperature: | 7 stage temperature programming |
Inlets | |
Various injectors available: | PPIP, SSI or Cool On-Column |
FID | |
Maximum temperature control: | **0℃ |
LOD: | ≤5**0‑*2g/s [n-C*6] |
Drift: | ≤5**0‑*3A/*0min |
Noise: | ≤2**0‑*3A |
Linear dynamic range: | ≥**7 |
TCD | |
Maximum temperature control: | **0℃ |
Sensitivity ratio: | ≥***0mv.ml/mg  [n-C*6] |
Drift: | ≤**0uV/*0min |
Noise: | ≤*0uV |
Linear dynamic range: | ≥**5 |
FPD | |
Maximum temperature control: | **0℃ |
LOD: |
≤2**0‑*3g/s(P) ≤5**0‑*1g/s(S) |
Drift: | ≤4**0‑*1A/*0min |
Noise: | ≤2**0‑*2A |
Linear dynamic range: |
≥**3(P) ≥**2(S) |
NPD | |
Maximum temperature control: | **0℃ |
LOD: |
≤5**0‑*3g/s(P) ≤1**0‑*2g/s(N) |
Drift: | ≤*5**0‑*2A/*0min |
Noise: | ≤4**0‑*3A |
Linear dynamic range: | ≥**3(P) |
ECD | |
Maximum temperature control: | **0℃ |
LOD: | ≤6**0‑*5g/ml  (γ***6) |
Drift: | ≤*0uV/*0min |
Noise: | ≤*0uV |
Linear dynamic range: | ≥**4 |
PDHID | |
LOD: | ≤5ppb |
Country: | China |
Model No: | GC5890N |
FOB Price: | 8800 ~ 28800 / Set Get Latest Price |
Place of Origin: | - |
Price for Minimum Order: | 8800 per Set |
Minimum Order Quantity: | 1 Set |
Packaging Detail: | standard export package |
Delivery Time: | 7 days after received deposit |
Supplying Ability: | 500 Set per Month |
Payment Type: | Western Union, D/P, D/A, L/C, T/T |
Product Group : | Gas Chromatograph |