FOB Price
Get Latest Price|
1 Unit Minimum Order
Country:
South Korea
Model No:
AB120 130 140
FOB Price:
Place of Origin:
South Korea
Price for Minimum Order:
-
Minimum Order Quantity:
1 Unit
Packaging Detail:
STANDARD PACKAGING
Delivery Time:
4 WEEKS
Supplying Ability:
5000 Unit per Month
Payment Type:
T/T
Product Group :
South Korea
Contact Person Mr. Daven
SAMJEONG DONG, BUCHEON, GYUNGKIDO
LOAD CELL
AB****3Kgf ~ *0Kgf
AB*****0Kgf ~ **0Kgf
AB******0Kgf, 1tf
-Low cost
-Off center compensated
-Protection Class IP*5
-Material: Aluminium
-Braided Shield *-Wire Round
(1) RATED CAPACITY
(R.C)
The maximum axial load that a
load cell is designed to measure with in its
specification
(2) RATED OUTPUT
(R.O)
The algebraic difference
between the outputs at on load and rated load. Usually load cell
output is specified in millivolts per volt at rated
capacity.
(3) NON-LINEARITY
The maximum deviation of the
calibration curve from a straight line between zero and rated load
outputs, expressed as a percent of the rated output and measured on
increasing load only.
(4) HYSTERESIS
The maximum difference between
output readings for the same applied load one point obtained while
decreasing from rated output. The points are taken on the dame
continuous cycle. The deviation is expressed as a percent of rated
output.
(5) REPEATABILITY
The ability of load cell to
reproduce output readings when the same load is applied to it
consecutively, under the same conditions, and in the same
direction. Repeatability is expressed
as the maximum difference
between output readings as a percent of rated
output.
(6) ZERO BALANCE
The output signal of the load
cell with rated excitation and with on load applied, usually
expressed in percent of rated output.
(7) TEMPERATURE RANGE,
COMPENSATED
The range of temperature over
which the load cell is compensated to maintain rated output and
zero balance
(8) TEMPERATURE RANGE,
SAFE
The range of temperature over
which the load cell may be safely operated up to full scale without
causing failure
(9) TEMPERATURE EFFECT ON
RATED OUTPUT
The change in rated output due
to a change in ambient temperature. Usually expressed as +/- a
percentage change in rated output per degree °C change in ambient
temperature, over the compensated temperature
range.
(*0) TEMPERATURE EFFECT ON
ZERO BALANCE
The change in zero balance due
to a change in ambient temperature. Usually expressed as +/- a
percentage change in the compensated temperature
range.
(*1) TERMINAL RESISTANCE,
INPUT
The resistance of the load
cell circuit measured at the excitation terminal. At standard
temperature, with no-load applied. And with The output terminals
open circulated.
(*2) TERMINAL RESISTANCE
OUTPUT
The resistance of the load
cell circuit measured at the output signal terminals, at standard
temperature, with no-load applied, and with excitation terminals
open circulated.
(*3) INSULATION
RESISTANCE
The DC resistance expressed in
ohms measured between any electrical connector pin or lead wire and
the load cell body or case. Normally measured at DC
*0V.
(*4)
EXCITATION
The voltage or current applied
to the terminals of the load cell.
(*5) SAFE
OVERLOAD
The maximum load in percent of
rated capacity which can be applied without causing a producing a
structural failure.
(*6) ULTIMATE
OVERLOAD
The maximum load in percent of
rated capacity which can be applied without producing a structural
failure.
(*7)
CREEP
The change in load cell output
occurring with time, while under load, and with all environmental
conditions and other variables remaining constant. Usually measured
with rated load applied and expressed as a percent
of
(*8)
ACCURACY
Stated as a limit tolerance
which deafness the average deviation between the actual output
versus theoretical output. In practical load cell applications, the
potential errors of nonlinearity, hysteresis, repeatability and
temperature effects do not normally occur simultaneously, nor are
they necessarily additive. Therefore, accuracy is calculated based
upon the RMS value of potential errors, assuming a temperature band
of ± *0 °C, full rated load applied, and proper set up and
calibration.
Potential errors of the read
out, cross talk, or creep effects are not
included.
Country: | South Korea |
Model No: | AB120 130 140 |
FOB Price: | Get Latest Price |
Place of Origin: | South Korea |
Price for Minimum Order: | - |
Minimum Order Quantity: | 1 Unit |
Packaging Detail: | STANDARD PACKAGING |
Delivery Time: | 4 WEEKS |
Supplying Ability: | 5000 Unit per Month |
Payment Type: | T/T |
Product Group : | LOAD CELL |