Mericonn Handheld fetal doppler
Function
1.Third gear operation mode
2.LCD digital display
3.Automatic shutdown without signal for *0 seconds
4.Intelligent noise reduction
5.Two listening modes
Responsibility of the
Manufacturer
The manufacturer only considers
itself responsible for any effects on safety, reliability and
performance of the equipment if:
Assembly operations, repairs are
carried out by persons authorized by the manufacturer, and the
device is used in accordance with the instructions for
use.
Responsibility of the
Manufacturer
The manufacturer only considers
itself responsible for any effects on safety, reliability and
performance of the equipment if:
Assembly operations, repairs are
carried out by persons authorized by the manufacturer, and the
device is used in accordance with the instructions for
use.
Warranty
The unit can not be repaired by
users themselves. All services must be done by the engineers
approved by manufacturer. We warrant that each product we sell you
is free from defects in labor and materials and shall conform to
its product specifications as defined in the user documentation. If
the product doesn't function as warranted during the warranty
period, we will repair or replace it without charge. Misuse,
improper maintenance may void the warranty.
This device is not intended for
treatment.The intended use is for
detecting Fetal Heart
Rate. If the FHR result is
distrustful, please use other methods such as stethoscope to verify
immediately.
Specification:
-Working
frequency: 2.0 MHz ± *0%
-Ultrasonic
output power:: Iob≤*0 mW/cm2
-Overall
Sensitivity: ≥ *0 dB (Integrated sensitivity **0mm away from the
the surface of the probe)
-While
measuring integrated sensitivity, using the Doppler frequency (**0
± *0) Hz
-Reflecting
target speed: *0cm / s ~ *0cm / s
-FHR
measuring range : No narrower than *0bpm***0bpm (± 2bpm). (Beat Per
Minute)
-FHR
Accuracy: ± 2 BPM
-Spatial-peak
temp-peak acoustic pressure:≤ 0.1 MPa.
-Negative
Peak Sound Pressure:(p_)<1Mpa
-Output
Beam Intensity:(Iob)<*0mW/cm2
Country: | China |
Model No: | FD200 |
FOB Price: | 18 ~ 15.9 / Box Get Latest Price |
Place of Origin: | Gungdong ,China |
Price for Minimum Order: | 18 per Box |
Minimum Order Quantity: | 1 Box |
Packaging Detail: | gift box |
Delivery Time: | 2 weeks for oem goods , 3~7 days for ready goods |
Supplying Ability: | - |
Payment Type: | T/T |
Product Group : | Fetal Doppler |