PTS controller
over fuel dispensers and ATG (automatic tank gauge) systems for
petrol stations serves as
a protocols
converter, it allows
conversion of proprietary communication protocols of dispensers and
ATG systems to a single communication protocol of PTS controller.
Thus the control system (POS system, cash register, payment
terminal) is able to provide control over any of the supported
dispensers and ATG systems in exactly the same way using a single
communication protocol of PTS controller. A work for a developer of
the control system is completely simplified - he does not need to
implement a great variety of the communication protocols in the
control system (which are difficult to get from manufacturers and
difficult to implement), he needs to implement only protocol of PTS
controller and PTS fuel pump controller will itself undertake
conversion of UniPump protocol to propritary communication
protocols of dispensers and ATG systems. Thus time required for
development of the control system is sufficiently
reduced.
PTS fuel pump controller can be called a forecourt controller and
is intended to be used in connection with a control system for
petrol station (POS system, cash register, OPT terminal, etc) to
provide simultaneous remote control over petrol, diesel, CNG and
LPG dispensers and automatic tank gauge (ATG) systems installed at
petrol, CNG and LPG stations and storage depots.
PTS controller provides control over any of the supported fuel
dispensers or ATG systems using the single common communication
protocol. PTS controller works as a protocol converter and provides
conversion of its common communication protocol into various
proprietary communication protocols of fuel dispensers and ATG
systems.
PTS fuel pump controller is supplied with a rich set of API
(application programming interfaces) developed under the most
commonly utilized programming languages and environments in order
to make comfortable and quick implementation of PTS controller into
control systems for petrol stations (POS system, cash register, OPT
terminal, etc).
PTS fuel pump controller can simultaneously control up to *6 fuel dispenser sides (fueling places). PTS controller has 4 independent pump channels, each of them can be programmed to its own communication protocol and baud rate, thus PTS controller provides communication with connected dispensers simultaneously using up to 4 various communication protocols. Each PTS controller pump channel can connect up to *6 fueling places maximum.
PTS controller can simultaneously control up to *6 ATG probes (gauges) (separate probes or probes connected to ATG systems / consoles) that use up to 3 various communication protocols and baud rates (each of the ATG channels can be adjusted to a separate communication protocol and baud rate and connect up to *6 ATG probes maximum).
PTS controller allows a possibility to lead management over the same fuel dispensers from several POS systems and share ATG probes measurement values between several interconnected PTS controllers. Thus every interconnected PTS controller is able to provide control over any of the connected fuel dispensers and know ATG system measurement data of every other interconnected PTS controller.
PTS controller supports more than *0 types of fuel dispensers brands of various manufacturers, between which you can find: Wayne Dresser Europe, Wayne Dresser Brasil, Gilbarco Veeder Root, Tokheim, Nuovo Pignone, Wayne Pignone, Tatsuno Japan, Tatsuno Europe, Tatsuno Rus, Tokico, Bennett, Petrotec, Salzkotten, FAS, Adast, MM Petro ZAP, Emgaz Dragon, Galileo, Kraus, Welma, PEC (Gallagher), Develco, Logitron, Kalvacha, Safe, Wayne Meksan, Mekser, Mepsan, 2A, Petposan, Petrolmeccanica, Batchen, Email, EuroPump, Baransay, Sanki, Korea EnE, LG EnE, SOMO Petro, HongYang, Blue Sky, GreenField, Falcon, Dong Hwa Prime, EPCO, Slavutich, Shelf, UniCon, UniGaz and others.
PTS controller supports various types of automatic tank gauge (ATG) systems of various manufactures (Gilbarco Veeder Root, OPW, Hectronic, Struna, PetroVend, Start Italiana, Fafnir, Assytech, VEGA, Windbell and others).
PTS controller is CE approved and has all corresponding test
reports.
FEATURES AND BENEFITS
Supports over *0 communication protocols of fuel dispensers and
ATG systems. List of supported communication protocols is
constantly growing. A wide range of international protocols as
Wayne DART, Gilbarco *-wire, Tokheim, Tatsuno are included.
Single firmware of PTS controller contains all available
communication protocols for fuel dispensers and ATG systems.
Unified approach to management over any forecourt equipment -
using PTS controller control over any supported fuel dispenser or
ATG system is done in exactly the same way by the management
system (POS system, cash register, OPT terminal, etc). PTS
controller has a single common communication protocol. Thus
having once implemented the protocol into the management system
(or its API) the management system will be able to provide
control over any of the supported fuel dispensers and ATG systems
in exactly the same way.
Real-time control over fuel dispensers and ATG systems. PTS
controller provides a hardware solution for stable and reliable
operation of forecourt equipment.
Scalability - PTS controller provides control over up to *6
dispenser sides, in case of necessity several PTS controllers can
work simutaneously.
Possibility to provide control over same fuel dispensers from
several POS systems and receive data on ATG measurements from any
interconnected PTS to each POS system - PTS controllers,
installed near each of the POS systems, can be interconnected
with each other allowing each of the POS systems to provide
control over each of the connected fuel dispensers or monitor its
state and to have data measurements of ATG systems connected to
any of the interconnected PTS controllers.
Rich set of interface converters for connection to fuel
dispensers - PTS controller has output pump channels in RS***5
interface so can be directly connected to fuel dispensers with
this type of interface. Other dispensers having communication
interface of *-wire current loop, *-wire current loop, *-wire
current loop, RS***2 interface are connected to PTS controller
through special interface converters.
Rich software API for developers - PTS controller is supplied
with full API (application programming interfaces) and
open-source test applications for common programming languages
and operation platforms: C, C++, C#, Delphi, Java, Python, Visual
Basic, COM-object.
"All in one" configuration tool for PTS controller: one
configuration utility provides configuration of its pump and ATG
channels, internal parameters, reads version, makes firmware
updates, captures logging from any channel and makes
self-diagnostics of the PTS controller.
Easy firmware updating - All new firmware updates are available
for download to all existing customers. Firmware update process
takes about 1 minute. Easy way to back up and restore PTS
controller configuration between updates.
Logging of operation - in order to remove problematic situations
of PTS controller communication with any forecourt equipment
logging of communication exchange without interrupting PTS
controller operation is available, which allows quick search and
elimination of any found problems.
Self-diagnostics of operation - easy and quick built-in
diagnostics of PTS controller operation: CPU, memory, RS***2 and
RS***5 interfaces, DIP-switches.
Constant software updates - PTS controller firmware is constantly
being improved, new protocols are being added and latest updates
are always available for download to all customers.
Support by developers for developers - *4 hours support for all
customers of PTS controller on any standing issues.
TECHNICAL CHARACTERISTICS
PARAMETER VALUE
Power supply voltage *2 V DC (version for *4 V
DC power supply is available upon request)
Current consumption **0 mA max
Temperature range from **0°C to **0°C
Weight **0 g
Overall dimensions **0 x *5 x *0 mm
SUPPORTED COMMUNICATION PROTOCOLS
Fuel dispensers communication protocols
Baud rate is configured for pump channel in PTS controller
independently on the used communication protocol.
Some dispensers may demand using interface converter boards to
RS***5 interface (depends on electronics of used pumphead in
dispenser).
## FUEL DISPENSER BRAND
PROTOCOL NAME
1 2A S*-Dart
2 ACTRONIC PEC Pump
Communication Protocol
3 ADAST (ADAMOV SYSTEMS)
Adast EasyCall
4 AG Walker SPDC*1,
MPDC*1
5 AGIRA PEC Pump
Communication Protocol,
PumpControl GC*1,
Develco
6 ANGI International Gilbarco
Two-Wire
7 Ariel PumpControl GC*1
8 ASPRO PumpControl GC*1,
Develco
9 BARANSAY Gilbarco
Two-Wire
*0 BATCHEN Gilbarco
Electroline,
Gilbarco MPP,
PumpControl GC*1,
Maser
*1 BENNETT Bennett pump
dispenser protocol (current loop),
Bennett pump dispenser protocol (RS***5 Fleet),
Bennett pump dispenser protocol (RS***5 Retail)
*2 BLUE SKY Blue
Sky,
SS-LAN
*3 CENSTAR Censtar
protocol
*4 CFT Clean Fuel Gilbarco
Two-Wire
*5 COMPAC PEC Pump
Communication Protocol,
Gilbarco Australia
*6 DATIAN MACHINES WS *6
communication protocol
*7 DEVELCO Develco
*8 DONG HWA PRIME Prime pump
interface
*9 EMGAZ DRAGON Marconi
PumaLAN
*0 EPCO EPCO protocol
*1 EUROPUMP S*-Dart
*2 FALCON LPG Falcon
*3 FORNOVO GAS Marconi
PumaLAN
*4 FUELQUIP PEC Pump
Communication Protocol
*5 FUELSIS S*-Dart
*6 GALILEO PumpControl
GC*1
*7 GILBARCO Gilbarco
Two-Wire
*8 GREENFIELD Gilbarco
Two-wire
*9 HONG YANG HongYang
FZ-protocol,
HongYang **6 communication protocol,
HongYang **6 MPD communication protocol
*0 IMW PumpControl
GC*1,
Tokheim UDC
*1 INTERMECH PEC Pump
Communication Protocol
*2 KALVACHA Kalvacha
*3 KIEVNIIGAZ TIT UniGaz
*4 KOREA ENE EnE Dispenser
POS protocol
*5 KPG*2 TIT UniGaz
*6 KRAUS Gilbarco
Two-Wire
*7 KWANGSHIN KS-NET
PROTOCOL
*8 LANFENG RS**2
protocols,
RS***5 protocol
*9 LG ENE EnE Dispenser POS
protocol
*0 LOGITRON Marconi Logitron
PumaLAN
*1 MASER Maser
*2 MEKSAN / WAYNE SU*6 WAYNE
Dart
*3 MEKSER S*-Dart
*4 MEPSAN S*-Dart
*5 MIDCO MIDCO Proprietary
Pump Protocol
*6 MS GAS SK PROTOCOL
*7 NUOVO PIGNONE Nuovo
Pignone RS***5,
Nuovo Pignone Current Loop *-wire,
Wayne Dart
*8 PEC (GALLAGHER FUEL SYSTEMS)
PEC Pump Communication Protocol,
Gilbarco Australia
*9 PETPOSAN S*-Dart
*0 PETROEQUIP Lanfeng
*1 PETROMECCANICA WAYNE
Dart
*2 PETROTEC PETROTEC HDX
protocol
*3 PROWALCO SPDC*1,
MPDC*1,
SPDC*2,
MPDC*2
*4 PUMP CONTROL PumpControl
GC*1
*5 REAL-TECH Blue
Sky,
SS-LAN
*6 RIX PEC Pump Communication
Protocol
*7 SAFE SAFE PMII
Graf,
PumpControl GC*1
*8 SALZKOTTEN ER*-Data
interface,
Gilbarco Two-Wire,
Marconi Logitron PumaLAN
*9 SANKI Sanki communication
protocol,
Sanki communication protocol for Nigeria,
Sanki communication protocol for CIS countries
*0 SEA BIRD Blue Sky
*1 SHELF Shelf
*2 SCHEIDT & BACHMANN
T*2,
V*1
*3 SCHIBATA SS-LAN
*4 SLAVUTICH SLAVUTICH
FD-Link
*5 SOMO PETRO POS
protocol
*6 TATSUNO (JAPAN) Tatsuno
SS-LAN
*7 TATSUNO EUROPE (FORMER BENC)
Tatsuno Benc PDE,
Logitron PumaLAN
*8 TOKHEIM Tokheim
Controller-Dispenser Communication protocol,
Logitron PumaLAN
*9 TOKICO Tokico SS-LAN
*0 TOMINAGA Tominaga
SS-LAN
*1 TOPAZ TOPAZ
Electro,
ISKRA ver. 1.*2
*2 TRANSPONDER PEC Pump
Communication Protocol
*3 UNICON-TIT TIT UniPump
*4 WAYNE DRESSER WAYNE
Dart,
Wayne US Current Loop
*5 WAYNE PIGNONE WAYNE
Dart
*6 YENEN S*-Dart,
Maser
*7 ZAP / MM PETRO MM PETRO
ZAP RS***5
Automatic tank gauge (ATG) systems communication protocols:
Communication parameters (baud rate, parity control, data and
stop bits) are configured for ATG channel in PTS controller
independently on the used communication protocol.
## ATG SYSTEM BRAND PROTOCOL
NAME
1 ACCU PD***0 Communication
Protocol
2 ASSYTECH Assytech
3 EBW Gilbarco Veeder
Root
4 ENRAF ENRAF Height
protocol,
ENRAF Volume protocol
5 FAFNIR FAFNIR
VISY-Quick,
Gilbarco Veeder Root
6 FRANKLIN FUELING GILBARCO
Veeder Root
7 GILBARCO Veeder Root (TLS*2, TLS***0,
TLS***0, TLS***0) GILBARCO Veeder Root
8 HECTRONIC HECTRONIC HLS
9 HUMANENTEC **0S
Communication Protocol
*0 INCON GILBARCO Veeder
Root
*1 LABKO Labkotec POS
interface protocol
*2 MTS ATG SENSORS MTS
USTD
*3 OMNTEC GILBARCO Veeder
Root
*4 OPW GILBARCO Veeder
Root
*5 PETRO VEND PETROVEND4
*6 START ITALIANA START
ITALIANA SMT/XMT,
Gilbarco Veeder Root
*7 STRUNA STRUNA Kedr spec.
1.4
*8 UNIPROBE UNIPROBE
*9 VEGA VEGA ASCII
protocol
*0 WINDBELL WINDBELL
SMART-PROBE COMMUNICATION PROTOCOL
Country: | Ukraine |
Model No: | - |
FOB Price: | 550 / ( Negotiable ) Get Latest Price |
Place of Origin: | - |
Price for Minimum Order: | 550 |
Minimum Order Quantity: | 1 Piece |
Packaging Detail: | - |
Delivery Time: | - |
Supplying Ability: | 10 Piece per Day |
Payment Type: | Money Gram, Western Union, T/T |
Product Group : | Controllers & Converters |