FOB Price
Get Latest Price1 ~ 2 / Set
|1 Set Minimum Order
Country:
China
Model No:
NAPF
FOB Price:
1 ~ 2 / Set Get Latest Price
Place of Origin:
China
Price for Minimum Order:
1 per Set
Minimum Order Quantity:
1 Set
Packaging Detail:
Adapt export wooden packaging standards SN-T 0273-2014
Delivery Time:
2~3 days after payment
Supplying Ability:
88888888 Set per Year
Payment Type:
L/C, T/T
Product Group :
Contact Person Ms. Liu
Wuhan, Hubei
Also
name
Pure resistance lightning pulse divider, high
voltage pulse impulse divider, pulse voltage divider, pure
resistance pulse voltage divider, the standard pure resistor
divider, lightning pulse voltage divider, the standard impact
voltage divider, high voltage pulse Voltage divider, standard pure
resistance lightning high voltage pulse impulse voltage
divider
Functional
overview
This equipment is equipped with high voltage
pulse voltage divider, collecting high frequency and power
frequency voltage signal, mainly used for lightning wave
measurement, power system overvoltage (operating over voltage,
ferromagnetic resonance overvoltage, series resonant overvoltage,
etc.) and the system Frequency voltage.
The high voltage pulse divider will serve as a
front-end component of the overvoltage on-line monitoring system,
providing the relevant attenuator and connected to the overvoltage
on-line monitoring system via a dedicated shielded cable for system
overvoltage monitoring.
1. a high voltage
side
A)
a high voltage side of the installation: from the high voltage
power grid bus access to the high voltage side of the high voltage
arrester and with the high side of the high voltage side of the
voltage divider to complete a high voltage side of the
installation. The voltage divider is single phase, divided into A,
B, C phase, single phase direct connection.
B)
can collect high frequency and frequency of the voltage
signal.
2. Secondary,
measurement monitoring side:
A)
secondary monitoring side wiring: the supplier is equipped with a
good voltage divider measurement output interface connector, the
supplier should be equipped with attenuator interface
connector, the middle is connected to the demand side of the
measurement cable signal The attenuator of the line and the
supplier forms the measurement loop. Intermediate connection of the
measurement cable signal line must be armored flame retardant tape
with the measurement cable signal line: coaxial *****1 or *****2 RF
shielding cable. Anti-interference ability of the best. Secondary
regulator side of the voltage divider Output port connector: Yes
SL*6 connector. Coaxial.
B)
The voltage output of the secondary side of the voltage divider is
**0V, and the voltage to the data acquisition mechanism is
*0V. The buffer (attenuator) needs to be
installed.
C)
Secondary output range: depending on the ratio of the partial
pressure ratio. Ratio of large voltage is low, the ratio of small
voltage high.
3. lightning high
voltage pulse divider works:
Coupled pulse current signal.
Main technical
data
1. High voltage
pulse divider parameters
Rated voltage: **0kV (0 ~ **0kV) a high voltage
side
Rated capacitance: ***0pF
Capacitance section: 1 section
Resistance and inductance: 0 ~ *0Ω, 0 ~
*0uH
Each section capacitance: ***0pF (MWF**0kV ~
***0pF pulse capacitor)
Square wave response: part of the response time
is less than **0ns, overshoot less than *0%
Partition ratio: **0: 1
Secondary side of the measurement port Output
voltage: **0V (0 ~ **0V)
Partition ratio Uncertainty (measurement
accuracy): less than 1%
Installation type: indoor or cabinet installation
requirements, synthetic silicone rubber casing insulation
shell.
Long-term operation in the *0kV power grid to
run, to meet the following waveform monitoring:
A. Standard
lightning impulse full-wave voltage
waveform
Wave head time: 1.2 ±*0%μs
Tail time: *0 ±*0%μs
Overshoot: less than 5%
Efficiency: no less than *0%
±
1.2 / *0μs
standard lightning impulse full-wave, the efficiency is greater
than *0%.
B. Standard
lightning impulse voltage
waveform
Wave head time: 1.2 ±*0%μs
Overshoot: less than 5%
Truncation time: 2 ~ 6μs,
electronic delay control
Efficiency: no less than *0%
Using the truncation device can produce
truncation time 2 ~ 6μs
lightning truncation, truncation dispersion is less than
**0ns.
C. Standard
operation shock full wave voltage
waveform
Wave time: **0 ±*0%μs
Tail time: ***0 ±*0%μs
Efficiency: not less than *0%
±
**0 / ***0μs
standard operating shock voltage wave, the efficiency is greater
than *0%.
D. produces steep
wave shock waveforms with steepness greater than ***0 kV /
μs
2. attenuator
(buffer) parameter
**0V / *0V ( / output)
Partition ratio: *0: 1
Attenuator for the voltage divider *0k ohm, to
prevent the voltage is too high, can access the monitoring
equipment to protect
Attenuator and output port of the
connector: are Q9 connector. Coaxial.
Coaxial connection connector and coaxial shield
measurement cable frequency AC voltage and lightning impulse
withstand voltage insulation level: ≤4kV.
Equipment
size
Dimensions: **0Hx**0Wx**0L (mm), single weight:
*5kg.
Installation size: **0Hx**0Wx**0L
(mm
Country: | China |
Model No: | NAPF |
FOB Price: | 1 ~ 2 / Set Get Latest Price |
Place of Origin: | China |
Price for Minimum Order: | 1 per Set |
Minimum Order Quantity: | 1 Set |
Packaging Detail: | Adapt export wooden packaging standards SN-T 0273-2014 |
Delivery Time: | 2~3 days after payment |
Supplying Ability: | 88888888 Set per Year |
Payment Type: | L/C, T/T |
Product Group : | High Voltage Withstand Device |