Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 11 Million Importers & Exporters globally. Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
poultry green house evaporative water wet curtain poultry green house evaporative water wet curtain
Next

poultry green house evaporative water wet curtain

FOB Price

Get Latest Price

80 USD / ( Negotiable )

|

110 Minimum Order

Country:

China

Model No:

poultry green house evaporative water wet curtain

FOB Price:

80 USD / ( Negotiable ) Get Latest Price

Place of Origin:

SHANDONG

Price for Minimum Order:

80

Minimum Order Quantity:

110

Packaging Detail:

carton

Delivery Time:

7day

Supplying Ability:

11110

Payment Type:

T/T

Contact Now

Contact Person Mr. Wang

Poultry cooling pad mannufacturingbase,Economic Development Zone,Qingzhou City, Weifang, Shandong

Contact Now

Product Description

 
Wet curtain cooling in the animal building negative pressure ventilation cooling Application
 
    Suitable for the animal building offers good climatic conditions for production efficiency is the decisive factor. In tropical and subtropical climatic conditions of the animal husbandry industry has always been suffering from the adverse effects of high temperatures. 
 
    Over the years, people have been looking for a hot climate industrialized agricultural production, low power consumption and reliable cooling measures. Practice shows that a "RDER wet curtain fan system," the evaporative cooling facilities are the most effective way to increase productivity.
 

 
    Usually the temperature at *0 ~ *5 ℃, relative humidity of not more than *5% of the animal husbandry is the best weather conditions. Temperature exceeds *5 ℃, will reduce the egg production performance of meat temperature will also reduce the breeding density. In other words, keeping homes cool the system will be installed to improve production performance.
 

 
    RDER Evaporative cooling system can reduce the animal body moisture to evaporate, thereby reducing the risk of dehydration, but also will work to improve indoor 
 
    For the environment. In the conventional cooling device without the ventilation system, air inlet temperature and the outdoor temperature is the same. However, because the sun's radiation, heat conduction, the heat hires animal itself, higher temperatures will lead to discounted homes than outside temperature of *0 ℃.
 

 
    RDER Evaporative cooling is a natural phenomenon. For example, when the wind blows across the sea will lead to moisture evaporation, so the air humidity drops.
 

 
    Animal building in order to artificially reproduce the physical process, you must have a surface allows water vapor, you need to make the surface wet the water supply system, need to let the air through the surface and make the system effective operation of the means of control.
 

 
RDER Site you need is the company's "RDER Site" wet curtain cooling system.
 

 
    RDER Site is the core cooling system allows water evaporation pad. RDER Site pad is bonded corrugated paper made of fibers, as in the raw materials to add a special chemical composition, which has a corrosion-resistant, long life characteristics.
 

 
    Special hydrophobic wet curtain to ensure that the cooling water evenly wet wet curtain wall to ensure contact with air completely wet the surface of the wet curtain. Installed in the premises of the other side of the exhaust fan to form a negative pressure zone hires, so that homes and outdoor air will be inhaled through the wet curtain discounted.
 

 
    Moist air through the wet curtain surface causes water to evaporate. Manipulation of the pump control system, and adjust the exhaust fan running Number of units, the power consumption is minimal.
 

 
    Ching-yao in the hot, the water content of the atmosphere is almost constant, which means that the highest values of humidity in the afternoon, its lowest relative humidity values. The lower relative humidity, the better the effect of evaporative cooling. In other words, that is cool when you need it most, it is also the best cooling effect.
 

 
    This is your pad from the RDER Site environmental performance characteristics of air-conditioning can get.
 

 
Help 
 
    RDER Site wet curtain system is run under negative pressure conditions. Wet curtain cooling installed in the animal building's side wall or side wall, and 
 
Exhaust fan is installed in the premises of the other side. Wet curtain cooling fan in the design of the system, we must pay great attention to discounted air velocity. Wind speed is too large, is not conducive to livestock production.
 

 
Animal building in the main heat source from the following three aspects: 
 
QA = animal body heat 
 
QR = solar radiation 
 
QT = thermal conductivity 
 
Livestock body heat generated by the livestock breeding and the number of hires and their body weight on 
 
Heat conduction and solar radiation by the heat generated depends on: 
 
Size of premises 
 
Structural Materials 
 
Insulation condition 
 
The following calculation is used for poultry house ventilation and the experience of data:
 

 
For the closed chicken house, 7 to 9 m 3 / h kg live weight 
 
For non-confined poultry house, at least *5 m 3 / h kg live weight 
 
Installation calculation 
 
These examples are illustrative and the chicken house ventilation rate needed to pad area: 
 
Assumptions: houses Size: **0 × *4 (m) 
 
Feeding capacity: *2,**0 
 
The average live weight: 1.5 kg 
 
Wind speed: 1.0 m / s (see performance curve)
 

 
1. Closed sheds 
 
Ventilation rate = ****0 (only) × 1.5 (kg / mouse) × 9.0 (m 3 / kg h) 
 
= **7,**0 m 3 / h = *2.5 m 3 / s
 

 
Pad area: *2.5 m 3 / s / 1.0 m / s = *2.5 m 2
 

 
That is at least an area of *2.5 square meters to be installed in the wet curtain. 
 
Discounted from the air inlet temperature to the outlet will inevitably be increased, with the wind, the discounted difference in temperature of about 3 ℃.
 

 
2. Non-enclosed chicken house 
 
Ventilation rate = ****0 × 1.5 × *5.0 = *****0 (m 3 / hour) = **7.5 (m 3 / s)
 

 
Pad area = **7.5 m 3 / s / 1.0 m / s = **7.5 m 2
 

That is at least an area of **7.5 square meters to be installed.

Country: China
Model No: poultry green house evaporative water wet curtain
FOB Price: 80 / ( Negotiable ) Get Latest Price
Place of Origin: SHANDONG
Price for Minimum Order: 80
Minimum Order Quantity: 110
Packaging Detail: carton
Delivery Time: 7day
Supplying Ability: 11110
Payment Type: T/T
Product Group : Evaporative Cooling pad
poultry green house evaporative water wet curtain
poultry green house evaporative water wet curtain

Related Products Rder International Investment Trade Co., Limited

Send a direct inquiry to this supplier

To:

Mr. Wang < Rder International Investment Trade Co., Limited >

I want to know: