FOB Price
Get Latest Price|
Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
-
Packaging Detail:
-
Delivery Time:
3 days since the payment arrive
Supplying Ability:
-
Payment Type:
-
Contact Person Ms. Leo
ShenNan Blvd.,, shenzhen, guangdong
Parameters: Five Parameters: ECG, NIBP, Pulse Rate, TEMP, SPO2. Waveforms: Two Waveforms: ECG waveform, SPO2 waveform (PLETH). Features: 1.Handheld; Compact, light, easy for carrying and handling. ***** and bright LCD small screen real time display, Touch Screen. ***** be display the data and the waveform in a screen, and also can be switch between ECG waveform and PLETH. ***** interface to simple read and handling. 5.Build-in rechargeable Ni/MH battery, longtime operating time. 6.Storage and review of patient trend data up to *6 hours which is never lost even when power is off. 7.Audio and visual alarm. 8.Battery capacity indicator. 9.Automatic power-off. *****: *******0 Net Weight: 0.6kg Gross Weight: 2.2kg Package Size: **0x**0x*0mm Standard accessories : one ECG cable with TEMP sensor one NIBP cuff with extend tube one SpO2 adult finger probe(soft) one charger one touch pen inside the model Technical specification Technical Specifications ECG Inputï&frac*4;š*-core ECG cable, standard AAMI cable connector Lead selectionï&frac*4;šIï&frac*4;ŒIIï&frac*4;ŒIII Gain selection:X1, X2, X4, X8 Frequency response: None filter: 0.*5ï&frac*2;ž**0Hz (*3dB) filter: 0.5ï&frac*2;ž*0Hz (*3dB) Scan Speed: *2.5, *5, *0 mm/S ECG standard signal: 1mV square wave generated by hardware Heart rate Measure range: *0ï&frac*2;ž**0 bpm Renew time: 1 time per beat Accuracy: 1 bpm Alarm limits range: Upper limits *0ï&frac*2;ž**0bpm, Lower limits *0ï&frac*2;ž**0 bpm Alarm mode: Audible and visual alarm NIBP Measure Method: Automatic oscillometric Average measure time: ï&frac*4;œ*0 seconds Repeat Cycles: 1, 2, 3, 5, *0, *5, *0, *0, *0 minutes Alarm limits range: SYS : Upper limits **0ï&frac*2;ž**0 mmHg, Lower limits *0ï&frac*2;ž**0 mmHg DIA : Upper limits *0ï&frac*2;ž**0 mmHg, Lower limits *0ï&frac*2;ž**0 mmHg MAP : Upper limits **0ï&frac*2;ž**0 mmHg, Lower limits *0ï&frac*2;ž**0 mmHg SpO2 Measure Range: *5ï&frac*2;ž**0% SpO2 Accuracy: 2%(*0ï&frac*2;ž*9%), 3%(*0ï&frac*2;ž*0%) Pulse Rate Range: 0ï&frac*2;ž**4 bpm Pulse Rate Accuracy: 1 bpm Alarm limits range: SpO2 upper limits : *5ï&frac*2;ž*9% lower limits: *5ï&frac*2;ž*6% Pulse Rateï&frac*4;škeep up with the heart rate Temperature Input : Apply the same sensor with ECG Measure range: 0ï&frac*2;ž*0℃ Alarm limits range: Upper limits *6ï&frac*2;ž*5℃ Lower limits *4ï&frac*2;ž*8℃ Measure accuracy: 0.1℃ System specifications Alarm ON/OFF: controlled by general switch and parameter switch (two levels) Display mode: Homochromy LCD hand touch screen Waveform channel: Single channel Trend data: **-hour HR, SpO2, TEMP, SYS, DIA, trend data. Dimensions: **4(D)X*5(H)X**0(W) mm