FOB Price
Get Latest Price|
Minimum Order
Place of Origin:
-
Price for Minimum Order:
-
Minimum Order Quantity:
-
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
-
Payment Type:
-
Contact Person Ms. Leo
ShenNan Blvd.,, shenzhen, guangdong
Characteristics Throughput: **0 test /hour Test mode: End –point, Kinetics, Fixed time Single and Double wavelength Linearity and Non-linearity calibration With and without reagent blank and (or) sample blank Can use Single reagent and double reagent Test range: clinical biochemistry, turbidimetry and immunoassay tests Setting of test: single parameter test, multi-parameters test, combined parameters, batch parameters test Setting of parameters: Completely open for editing test parameters, editing combined parameters and calculating parameters Bench top compact automatic analyzer Routine & STAT tests available User-friendly, safe handling Technical Parameters Optical system Light source: *2V/*0W Halogen lamp, life span>***0h Wavelength: *1 interference filters: **0, **0, **5, **0, **2, **5, **6, **8, **0, **0 And **0nm Sample system Sample plate: two rotor rings, *4 positions for samples, all positions can be assigned as sample, standard, quality control and blank Sample volume: 5ï&frac*2;ž*0ul Sample auto-dilution: instrument dilutes and retests the sample automatically Sample needle: Auto liquid level detection function; auto-wash inner and outer wall Reagent system Sample plate: *0 reagent positions, all positions can be assigned as R1, R2 Reagent bottle volume: *0ml Reagent refrigeration and heating: 4ï&frac*2;ž*0℃ Crefrigeration and reagent preheating functions Reagent volume: *0ml Reagent needle: Auto liquid level detection function; auto-wash inner and outer wall Reaction system Reaction plate: turnable reaction plate, *6 disposable reaction cuvettes Reaction Temperature: *7℃, temperature accuracy is ±0.1℃ Quality control: 3 control sera levels, calculating statistical results automatically, levey-jennings QC plot. Real-time inquiry the QC, print QC results and QC plot Data system: Computer control: Windows XP system Data processing: large capacity can store test results, display, save and print reaction curve Print: edit and print the completed English report, can choose and edit the printing content, support the net work report printing Working environment: Power supply: AC**0V±*0%, *0Hz±2% Electric power consumption: <**0VA Environmental Temperature: *5ï&frac*2;ž*2℃ Relative humidity: ﹤*5% Water consumption: <***0ml/hour