Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 11 Million Importers & Exporters globally. Join Now |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
CMS50D+ Pulse Oximeter

CMS50D+ Pulse Oximeter

FOB Price

Get Latest Price

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

1unit

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contact Now
Free Member

Contact Person Mr. Mark

HUANGHEWEST, Qinhuangdao, Hebei

Contact Now

Description

Major Features â Integrated with SpO2 probe and processing display module â Small in volumeãlight in weight and convenient in carrying â Operation of the product is simple , low power consumption â Operation menu for the function setting â SpO2 value display â Pulse rate value display, bar graph display â Pulse waveform display â The display mode can be changed â A pulse rate sound indication â With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable â Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function â With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers â Real-time data can be transmitted to computers â Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe â RF Wireless communication function(Option) â Connected with an external oximeter probe(Option) Main performance Display Mode: 0.*6" Dual color OLED display Screen Resolution: **8**4 SpO2 Measuring Range: 0%ï&frac*2;**0%, (the resolution is 1%). Accuracy: *0%ï&frac*2;**0%: ±2% , Below *0% unspecified. PR Measuring Range: *0bpmï&frac*2;**0bpm, (the resolution is 1bpm) Accuracy: ±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Power Consumption: less than *0mA Voltage: DC 3.0V Power Supply: 1.5V (AAA size) alkaline batteries à 2 Battery Working Hour: The minimum continually work time is *4 hours , theoretical number is *2 hours. Safety Type: Interior Battery, BF Type Passed CE

Send a direct inquiry to this supplier

To:

Mr. Mark < Contec Medical Systems >

I want to know: