Power input | Rated input voltage |
*-phase
AC**8V/AC**0V/AC**0V/AC**0V/AC**0V/AC**0V/AC**5V/AC**0V/AC**0V/AC**0V *-phase AC**0V/AC**0V/AC**0V |
|
Rated input current | See Section 2.3 in user manual | ||
Frequency | *0Hz/*0Hz, tolerance ±5% | ||
Allowable range of voltage |
Continuous voltage fluctuation ±*0%,
short fluctuation **5%~**0%, i.e. **3V~**8V; Voltage out-of-balance rate <3%, distortion rate as per the requirements of IEC******2 |
||
Power output | Standard applicable motor (kW) | See Section 2.3 in user manual | |
Rated current (A) | See Section 2.3 in user manual | ||
Output voltage (V) | *-phase: 0~ rated input voltage, error < ±3% | ||
Output frequency (Hz) | 0.*0~ **0.*0Hz; unit: 0.*1Hz | ||
Overload capacity | **0% - 1min; **0% - *0s; **0% - 0.5s,once per *0 minutes | ||
Operational control characteristics | V/HZ patterns |
V/f control Sensor-less vector control 1 Sensor-less vector control 2 |
|
Range of speed regulation |
1:**0 ( V/f control, sensor-less
vector control 1) 1:**0 (sensor-less vector control 2) |
||
Speed accuracy |
±0.5% (V/f control) ±0.2% (sensor-less vector control 1 & 2) |
||
Speed fluctuation | ±0.3% (sensor-less vector control 1 & 2) | ||
Torque response |
< *0ms (sensor-less vector control 1 & 2) |
||
Starting torque |
0.5Hz: **0% (V/f control,
sensor-less vector control 1) 0.*5Hz: **0% (sensor-less vector control 2) |
||
Basic functions | Start frequency | 0.*0~ **0.*0Hz | |
Acceleration/ deceleration time |
0.*0~****0s | ||
Carrier frequency | 0.7kHz~*6kHz | ||
Frequency setting sources |
Digital setting + keypad
∧/∨ Digital setting + terminal UP/DOWN Communication Analog setting (AI1/AI2/EAI) Terminal pulse setting |
||
Motor started methods |
Started from starting
frequency DC braking and then started Speed follow-up started |
||
Motor stopped methods |
Ramp to stop Coast to stop Ramp stop + DC brake |
||
Basic functions | Dynamic braking capacity | Brake unit action voltage: **0V~**0V; service time: 0.0~**0.0s; brake units for GK****4T*5G/*5L and below are built in or can be built in. See table **1 | |
DC braking capacity |
DC braking start frequency:
0.*0~**0.*0Hz DC braking current: 0.0~**0.0% DC braking time: 0.0~*0.*0s |
||
Input terminals |
6 digital inputs, one of which can
be used for high-speed pulse input. Compatible with active open
collectors NPN, PNP and dry contact input. Digital inputs can be
extended to 7 2 analog inputs, one of which is voltage/current programmable, and the other is voltage only. Analog inputs can be extended to 3, and the extended one is voltage/current programmable |
||
Output terminals |
1 high-speed pulse output, 0~*0kHz
square wave signal output; can output signals such as setting
frequency, output frequency, etc. 1 digital output 1 relay output (can be extended to 2) |
||
1 analog output (can be extended to 2), voltage/current output programmable; can output signals such as setting frequency, output frequency, etc | |||
Featured functions | Parameter copy, parameter backup, common DC bus, free switching between two motors’ parameters, flexible function code displayed & hidden, various main & auxiliary command and switchover, speed searching, a variety of acceleration/deceleration curves optional, automatic correction of analog value, mechanical brake control, **-step speed control programmable (*-step speed supports flexible frequency command), swing frequency control programmable, fixed-length control, counting function, three faults recorded, over excitation braking, over voltage stall prevention, under voltage stall prevention, restart upon power off, hopping frequency, frequency binding, free switching between four sections of acceleration/deceleration time, motor thermal protection, flexible fan control, process PID control, simple PLC, flexible multi-functional key setting, droop control, parameter identification, weak magnetic control, high-precision torque restraint, V/f separated control | ||
Protection functions | Refer to Chapter VII – Troubleshooting in user manual | ||