HSW1 Series Air Circuit Breaker
1 Application
HSW1 Series ACB could be suitable for the distribution network of
AC Current *0Hz/*0Hz, the rated voltage up to ***0V with rated
current from **0A to ***0A ,used to distribute electric energy,
protection circuit and power supply equipment against harm from
overload, under-voltage, short circuit and single-phase ground
fault. The ACB has intelligent protect function and precise
protection of Selective (The first one supply continue adjustable
technique and has excellent friendly human-computer dialogue
technology) meanwhile in order to meet the requirements of control
center and automation system. It has an open communication
interface with four remote functions (remote telemetry, remote
tuning, remote communication and remote control).The breaker
complies with requirements specified in IEC******2 LV Circuit
Breaker of LV Switchgear and Control gear.
2.Type designation and classification
2.2.1 In terms of installation mode:
Fixed type
Withdraw type
2.2.2 Based on pole number
Three-pole
Four-pole
2.2.3 According to operating mode
Motor-driven operation
Manual operation (for reparation and maintenance)
Release
Intelligent release, under voltage instantaneous (or time delay)
release and shunt release.
2.4 Intelligent controller
a) The intelligent controller may be divided into L Type
(economical), M Type (typical) and H Type (communicative).
b)With overload long time delay (inverse time limit), short time
delay (definite time limit) and instantaneous trip functions.
c)Phase earthing accident protection.
d) Display: Setting current, operational current, running current,
line voltage (this information should be noted when ordering).
e)Alarm: Overload pre-alarm.
f)Self-diagnose: Overheat, PC self-diagnose.
g)Test function: To test the operation characteristics of the
controller.
3.Working conditions and installing conditions
3.1 Ambient temperature ranging from *5ºC to **0ºC, average
value within *4 hours not over **5ºC;
3.2 Altitude not exceeding ***0 meters above sea level;
3.3 Relative humidity not over *0% at **0ºC yet higher
humidity is permissible at lower temperature. The
maximum value is *0% in the most humid month of the year and
meanwhile the minimum temperature in the month is **5ºC;If working
conditions are other than the mentioned above, discussions should
be made with the manufacturer.
3.4 Degree of protection: IP *0; Pollution
grade: III
3.5 Category of application: B
Installing category:
IV for circuit breakers, under-voltage releases and power
transformer primary coils with rated voltage up to **0V
(**0V);
III for auxiliary circuits and control circuits.
Installing conditions:
The circuit
breakers should be installed according to this manual. The
vertical inclination should not exceed 5°. If it is the
mineral circuit breaker, the vertical inclination should not be
over *5°.
Technical parameters and performances
The rated current of the breaker is shown in Table 1
Table 1
Rated frame current I nm (A) | Rated current I n (A) |
***0 | **0, **0, **0, **0, ***0 |
***0 | **0, **0, ***0, ***0, ***0, ***0 |
***0 | ***0, ***0, ***0, ***0 |
***0 | ***0, ***0, ***0 |
***0 | ***0, ***0, ***0 |
Rated frame current I nm (A) | ***0 | ***0 | ***0 | ***0 | ***0 | |
Rated limited short circuit breaking capacity I cu (kA) O - CO |
**0V | *2 | *0 | **0 | **0 | **0 |
**0V | - | *0 | *5 | *5 | *5 | |
Rated short circuit making current n×I cu (kA) / cos φ |
**0V | *8.2/0.*5 | **6/0.2 | **0/0.2 | **0/0.2 | **4/0.2 |
**0V | - | **5/0.*5 | **3/0.2 | **3/0.2 | **7/0.2 | |
Rated service short circuit breaking capacity Ics (kA) O - CO - CO |
**0V | *0 | *0 | *5 | **0 | **0 |
**0V | - | *0 | *5 | *5 | *5 | |
Rated short time withstand current Icw(kA) 1s time delay 0.4s, O - CO |
**0V | *0 | *0 | *5 | *0 | *0 |
**0V | - | *0 | *5 | *5 | *5 |
Country: | China |
Model No: | HSW1 |
FOB Price: | 695 ~ 700 / Piece ( Negotiable ) Get Latest Price |
Place of Origin: | ZHEJIANG CHINA |
Price for Minimum Order: | 695 per Piece |
Minimum Order Quantity: | 5 Piece |
Packaging Detail: | Wooden box |
Delivery Time: | 30-40DAYS |
Supplying Ability: | 50000 Piece per Year |
Payment Type: | PayPal, T/T |
Product Group : | - |